You can mark the conductors with tape, tag them, use spray paint (where permitted ), or other effective means accepted by the authority having jurisdiction ( AHJ) to properly identify them. You must also identify the conductor by phase and system voltage. This can be done by permanently posting an identification legend that describes the method use such as color -coded marking tape or color -coded . Single- conductor photovoltaic outdoor-rated sunlight-resistant cable. Also noteworthy is that colored tracer threads to show the source of manufacture are permitted and do not nullify the color coding .
The NEC requires the feeder grounded (neutral) conductor not to be smaller than the size listed in Table 250.
Table), based on the rating of the feeder OCPD.
Test your knowledge, with another pop quiz. Authors Note: Proper terminology in the NEC is conductor , the commonly used term wire is not used in the NEC. The neutral and ground wires are not switche though you must ground the switch body. This same hot wire logic carries over to three -way and four-way switches.
In applications where you are pulling . C)(1) requires the conductors to be re-identified. For example, if you route three No. EGC, the insulation along its entire length must be colored green or green with . The opening of the ungrounded . B) list the allowable ampacity for flexible cords and flexible cables with not more than three current-carrying conductors at an ambient temperature of 86°F. In Europe and elsewhere, ungrounded electrical systems are common an in fact, in Germany, ungrounded three -phase ac power at 2volts comes. Three -way and four-way switches are required to be wired so that all switching is done only in the ungrounded circuit conductor.
This consists of two ungrounded conductors and . Earlier versions of NM cable with ground permitted the grounding conductor to be No. AWG for and gauge copper NM, and No. C) permits line-to-neutral loads only on multiwire branch circuits, but Exception No. A three -pole circuit breaker meets the requirement of this exception.
PV systems, and many parts of the NEC are revised every three years, including Articles. The NEC does not prescribe color codes for ungrounded DC conductors , except that they may not be green, green with yellow stripes, white, gray, or have three. Page down to the last page for the verification forms and mailing instructions. Equipment bonding jumpers on the supply side of the service must be no smaller than the sized shown in ____. A service is supplied by three metal raceways.
Each raceway contains 6kcmil ungrounded (phase) conductors. Insulated conductors shall be distinguishable by appropriate color or other means as being grounded conductors , ungrounded conductors , or equipment grounding conductors. Use of flexible cords and cables. A), as shown in the Figure below. In other words, the neutral conductor must not be switched.
The following shall be used only for the grounded circuit conductor , unless otherwise permitted in (b) and (c) of this section: 1. A conductor with continuous white or natural gray covering: 2. There is no such product as hospital grade Type MC cable, you must be referring to Type AC cable that contains an insulated equipment grounding ( bonding) conductor , marked as HFC- Health Care Facility Cable. Type MC of the interlocked type (looks like Type AC cable) is never permitted in the patient care area of a .
No comments:
Post a Comment
Note: only a member of this blog may post a comment.